The balance is made up by
a microprocessor electronic system contained in a box DIN
43700, by a small local amplifier for each weighing group
and by an external power card for every two weighing
groups.
Electrical connections are simplyfied by direct insertion
on the back panel.
Depending on the configuration requested a weighing
system can control two, three or four weighing groups.
Each group is provided with four digit displays showing
the weight and with two leds: alarm and final weight
indicator.
The displays referred to balance #1 and #4 are grouped in
a nine digits single line to display long data and for
programming purpose.
Using the keyboard it is possible to visualize or modify
datas which refears to the selected function ( F1 - F11 )
each indicated by its own led. All programming datas and
results such total weights or counts are retined even
when the power is off.
In a simple way it is possible to recall till 99
previously stored programs.
|
- local amplification of the
load cell signal to assure an eccellent electrical noise immunity.
- vibration frequency selectable to optimize the
flow of different kind of products.
- vibration intensity indipendently selectable
for each vibrator (till 4 vibrators for each weighing group).
- autozeroing: if enabled allow the automatic
tare refresh.
- autocontrol: if enabled allow the automatic
correction of eventual eccess tendency.
- displayng and printing ( optional ) of
production data.
- PNP or NPN logic inputs.
- maximum range for each group: 1999 gr with +/-1
gr resolution.
- mechanical dimensions: hight mm 192, breadth mm
96, length mm 280.
- reduced or special
configurations for one or two weighing groups even with
increased ranges availables
|
- F1 vibrators
intensity
- F2 tare
- F3 bulk feed level
- F4 fine feed level
- F5 accumulation time
- F6 flying feed correction
- F7 + tolerance
- F8 - tolerance
|
- F9 verify delay
- F10 product code
- F11 time
-
F9 +2nd discharge time
- F10 +2nd line code
- F11 +2nd date
|
- Total weight
- = weight
- + weight
- - weight
- Total count
- = count
- + count
- - count
|
home
| contact | top
|